Leak Detection
Non Penetrating Leak Detection
A
unique leak detection system that does not penetrate
the liner, consisting of perforated tube and dip
stick, is positioned between the primary and secondary
liners. Any leakage through the primary liner is
collected in
the tube and measured on the dip stick. Fabricated
primarily from PVC components, the system is available
in other plastics or metals.
A: Primary Liner
B: Perforated Tube
C: Dip Stick
D: Geotextile
E: Secondary Liner
Bottom
Sump Leak Detection
Leak
detection systems utilizing double liners with the
secondary liners connected to leak detection sumps
are available.
A: Primary Liner
B: Geotextile
C: Secondary
Liner
D: Cover Plate
E: Flange/Sump
Sight
Glass Leak Detection
Fluid
that penetrates the primary liner is collected by
a geotextile interlayer and
wicked to thru-the-wall fittings for instant inspection
in an external sight glass.